Hitachi Compute Blade 2000 User Manual page 841

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

ID
Level
Description: The temperature of the CPU in Location Y has reached Error level. X shows
either Upper (high temperature) or Lower (low temperature) at error level. The specified
module may be stopped for hardware protection.
Action: The specified module may be stopped for hardware protection. Contact your reseller
or maintenance personnel.
Check if anything interferes with the cooling system. When finding some factors interfering
with cooling, such as malfunction in the cooling equipment or in fan modules in the system,
and dust-covered intake, remove the problem factor. If the temperature does not return to the
normal when you have removed it, contact your reseller or maintenance personnel.
Temperature of CPU has been restored to a normal level.
FD05
Information
(Temp(X),Location:Y)
Description: The temperature of the CPU in Location Y has recovered to the normal level. X
shows either Upper (high temperature) or Lower (low temperature) at error or warning level.
Action: None. This is a recovery message.
FD10
Warning
Voltage became warning level. (Voltage(X), Location:Y)
Description: The voltage of the location shown as Y has reached Warning level. X shows
either Upper (high voltage) or Lower (low voltage) at warning level.
Action: The state may go up to a higher error level, FD11, although you can keep operations
running. Contact your reseller or maintenance personnel.
FD11
Error
Voltage became error level. (Voltage(X), Location:Y)
Description: The voltage of the location shown as Y has reached Error level. X shows either
Upper (high voltage) or Lower (low voltage) at error level.
Action: The specified module may be stopped for hardware protection. Contact your reseller
or maintenance personnel.
FD12
Information
Voltage has been restored to a normal level. (Voltage(X),Location:Y)
Description: The voltage of the location shown as Y has recovered to the normal level. X
shows either Upper (high voltage) or Lower (low voltage) at error or warning level.
Action: None. This is a recovery message.
FD30
Information
Module is installed. (Location:X)
Description: The module shown in Location X is installed.
Action: None.
FD31
Information
Module is removed. (Location:X)
Description: The module shown in Location X is removed.
Action: None.
FD38
Error
Watchdog timer has expired. (Location:X)
Description: A watchdog timeout is detected in Location X.
Action: Contact your reseller or maintenance personnel.
FD40
Warning
On server, a warning event occurred. (Location:X,Event:Y)
Description: A warning event has occurred in the server blade. X shows a position that the
event occurred; Y describes the event.
Action: Contact your reseller or maintenance personnel.
FD41
Error
On server, an error event occurred. (Location:X,Event:Y)
Description: An error event has occurred in the server blade. X shows a position that the
event occurred; Y describes the event.
Action: Contact your reseller or maintenance personnel.
FD42
Information
Server has been restored to a normal level. (Location:X,Event:Y)
Description: The server blade has recovered to the normal state. X shows a position that the
event occurred; Y describes the event.
Action: None. This is a recovery message.