Suspicious-Control-Flow-Detection Protocol Low-Threshold - Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - COMMAND REFERENCE N TO Z 2010-10-19 Command Reference Manual

Software for e series broadband services routers command reference n to z
Table of Contents

Advertisement

suspicious-control-flow-detection protocol low-threshold

Syntax
Release Information
Description
Options
Mode
Copyright © 2010, Juniper Networks, Inc.
suspicious-control-flow-detection protocol protocolValue
low-threshold lowThresholdValue
no suspicious-control-flow-detection protocol protocolValue low-threshold
Command introduced in JunosE Release 7.3.0.
Sets the low threshold rate at which a suspicious flow becomes no longer suspicious for
a specific protocol. The no version restores the default for a protocol, which is a
protocol-dependent non-zero numeric value.
protocolValue—Name of the protocol
lowThresholdValue—Threshold value in packets per second; 0 or a number in the range
1–32767; a value of zero means that a suspicious flow cannot change to the
nonsuspicious state via a threshold; a flow can only become nonsuspicious via a backoff
time; if the low threshold value is zero and the backoff time is zero, the flow can only
be considered nonsuspicious if the rate (in packets per second) goes to zero