t1 clock source

Syntax
Release Information
Description
Options
Mode
Copyright © 2010, Juniper Networks, Inc.
t1 channel clock source { line | internal { module | chassis } }
no t1 channel clock source
Command introduced before JunosE Release 7.1.0.
Determines which end of the T1 interface provides clocking. The no version uses the
default value, line.
channel—One or more individual T1 channels, ranges of T1 channels, or combination
of individual channels and ranges, in the range 1–28 (no spaces); for example,
3,7-15,19-13,27
line—Interface transmits data from a clock recovered from the line's receive data
stream
internal—Interface transmits data using its internal clock. You must specify one of the
following for internal clocking:
module—Internal clock is from the line module itself
chassis—Internal clock is from the configured system clock
Controller Configuration