threshold

Syntax
Release Information
Description
Options
Mode
Copyright © 2010, Juniper Networks, Inc.
threshold { sd-ber | sf-ber } rate
no threshold { sd-ber | sf-ber }
Command introduced before JunosE Release 7.1.0.
Sets the threshold values for bit error rates used in APS/MSP alarms. This command
applies only to the protect interface, and not to the working interface. The no version
restores the default value, 5 (for the sd-ber bit error rate) or 3 (for the sf-ber bit error
rate), for the specified alarm.
sd-ber—Bit error rate that specifies signal degradation
sf-ber—Bit error rate that specifies signal failure
rate—Integer n with available values depending on the bit error rate type you specify;
a value of n corresponds to a rate of 10-n (10e-n) errors per second
For sd-ber, an integer in the range 5–9; default value is 5
For sf-ber, an integer in the range 3–5; default value is 3