Timers Spf - Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - COMMAND REFERENCE N TO Z 2010-10-19 Command Reference Manual

Software for e series broadband services routers command reference n to z
Table of Contents

Advertisement

JunosE 11.3.x Command Reference Guide N to Z

timers spf

Syntax
Release Information
Description
Options
Mode
1312
[ no ] timers spf holdTime
Command introduced before JunosE Release 7.1.0.
Configures the delay time between when OSPF receives a topology change and when it
starts an SPF calculation and the hold time between two consecutive SPF calculations.
The no version restores the default value.
holdTime—Number in the range 1–5 seconds; default value is 3; the hold time between
consecutive SPF calculations