JUNOS 10.1 Network Interfaces Configuration Guide
ppp-options
ppp-options {
Syntax
}
[edit interfaces interface-name],
Hierarchy Level
[edit interfaces interface-name unit logical-unit-number],
[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number]
Statement introduced before JUNOS Release 7.4.
Release Information
lcp-restart-timer statement introduced in JUNOS Release 8.1.
ncp-restart-timer statement introduced in JUNOS Release 8.1.
loopback-clear-timer statement introduced in JUNOS Release 8.5.
dynamic-profile statement introduced in JUNOS Release 9.5.
On interfaces with PPP encapsulation, configure PPP-specific interface properties.
Description
For ATM2 IQ interfaces only, you can configure CHAP on the logical interface unit if
the logical interface is configured with one of the following PPP over ATM
encapsulation types:
The remaining statements are explained separately.
1354
ppp-options
chap {
access-profile name;
default-chap-secret name;
local-name name;
passive;
}
compression {
acfc;
pfc;
}
dynamic-profile profile-name;
lcp-max-conf-req number
lcp-restart-timer milliseconds;
loopback-clear-timer seconds;
ncp-max-conf-req number
ncp-restart-timer milliseconds;
pap {
access-profile name;
default-pap-password password;
local-name name;
local-password password;
passive;
}
atm-ppp-llc
—PPP over AAL5 LLC encapsulation.
—PPP over AAL5 multiplex encapsulation.
atm-ppp-vc-mux