Xerox WorkCentre 5687 Series Service Manual page 1991

Table of Contents

Advertisement

Table 6 NVM chain 20
Location NVM Name
NVM Description
20-759
Dtone1FlgDetctP
Dtone 1 flag detection per-
erfd2
formed 2
20-760
FaxDtone1Make
Dtone 1 make min 3
Min3
20-761
FaxDtone1Make
Dtone 1 make max 3
Max3
20-762
FaxDtone1Make
Dtone 1 make hole 3
Hole3
20-763
FaxDtone1Break
Dtone 1 break min 3
Min3
20-764
FaxDtone1Break
Dtone 1 break max 3
Max3
20-765
FaxDtone1Break
Dtone 1 break hole 3
Hole3
20-766
FaxDtone1IdxNx
Dtone 1 idx next cell 3
tCell3
20-767
Dtone1IdxRestrt
Dtone 1 idx restart cell 3
Cell3
20-768
Dtone1FlgDetctP
Dtone 1 flag detection per-
erfd3
formed 3
20-769
Dtone2DetctAlgo
Dtone 2 detection algorithm Range = 32 to 33
rithm
20-770
DtoneNumCell-
Dtone 2 number cell pattern Number of ring pattern
Pattern
20-771
DtoneTmoutRe-
Dtone 2 time out reset
setDetct
detector
20-772
FaxDtone2Make
Dtone 2 make min 1
Min1
20-773
FaxDtone2Make
Dtone 2 make max 1
Max1
20-774
FaxDtone2Make
Dtone 2 make hole 1
Hole1
20-775
FaxDtone2Break
Dtone 2 break min 1
Min1
20-776
FaxDtone2Break
Dtone 2 break max 1
Max1
20-777
FaxDtone2Break
Dtone 2 break hole 1
Hole1
20-778
FaxDtone2IdxNx
Dtone 2 idx next cell 1
tCell1
20-779
Dtone2IdxRestrt
Dtone 2 idx restart cell 1
Cell1
20-780
Dtone2FlgDetctP
Dtone 2 flag detection per-
erfd1
formed 1
WorkCentre 5687 Family
Value
Default
Location NVM Name
Is this the last detection
0
20-781
pattern? Range = 0 to 1
Range = 0 to 10000 ms
0
20-782
Range = 0 to 10000 ms
0
20-783
Range = 0 to 10000 ms
0
20-784
Range = 0 to 10000 ms
0
20-785
Range = 0 to 10000 ms
0
20-786
Range = 0 to 10000 ms
0
20-787
Index of next pattern.
0
20-788
Range = 0 to 2
Index to restart at.
0
20-789
Range = 0 to 2
Is this the last detection
0
20-790
pattern? Range = 0 to 1
32
20-791
0
20-792
detectors. Range = 0 to 3
Range = 1 to 15000 ms
100
20-793
Range = 0 to 10000 ms
0
20-794
Range = 0 to 10000 ms
0
20-795
Range = 0 to 10000 ms
0
20-796
Range = 0 to 10000 ms
0
20-797
Range = 0 to 10000 ms
0
20-798
Range = 0 to 10000 ms
0
20-799
Index of next pattern.
0
Range = 0 to 2
20-800
Index to restart at.
0
Range = 0 to 2
Is this the last detection
0
pattern? Range = 0 to 1
August 2007
6-99
Table 6 NVM chain 20
NVM Description
FaxDtone2Make
Dtone 2 make min 2
Min2
FaxDtone2Make
Dtone 2 make max 2
Max2
FaxDtone2Make
Dtone 2 make hole 2
Hole2
FaxDtone2Break
Dtone 2 break min 2
Min2
FaxDtone2Break
Dtone 2 break max 2
Max2
FaxDtone2Break
Dtone 2 break hole 2
Hole2
FaxDtone2IdxNx
Dtone 2 idx next cell 2
tCell2
Dtone2IdxRestrt
Dtone 2 idx restart cell 2
Cell2
Dtone2FlgDetctP
Dtone 2 flag detection per-
erfd2
formed 2
FaxDtone2Make
Dtone 2 make min 3
Min3
FaxDtone2Make
Dtone 2 make max 3
Max3
FaxDtone2Make
Dtone 2 make hole 3
Hole3
FaxDtone2Break
Dtone 2 break min 3
Min3
FaxDtone2Break
Dtone 2 break max 3
Max3
FaxDtone2Break
Dtone 2 break hole 3
Hole3
FaxDtone2IdxNx
Dtone 2 idx next cell 3
tCell3
Dtone2IdxRestrt
Dtone 2 idx restart cell 3
Cell3
Dtone2FlgDetctP
Dtone 2 flag detection per-
erfd3
formed 3
FaxMaxAutore-
The maximum range for the
dials
auto re-dial attempts dis-
played in SA/KO. Linked to
ID204
LowimpAt-
Application of very low
LineSeize
impedance for approxi-
mately 350 ms at line sei-
zure.
Value
Default
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Index of next pattern.
0
Range = 0 to 255
Index to restart at.
0
Range = 0 to 2
Is this the last detection
0
pattern? Range = 0 to 1
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Range = 0 to 10000 ms
0
Index of next pattern.
0
Range = 0 to 2
Index to restart at.
0
Range = 0 to 2
Is this the last detection
0
pattern? Range = 0 to 1
Range = 0 to 14
0
0 = Disabled
0
1 = Enabled
General Procedures & Information
dC131b

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: