Xerox WorkCentre 5687 Series Service Manual page 1975

Table of Contents

Advertisement

Table 9 NVM chain 10
Location NVM Name
NVM Description
10-059
Card stock offset
Media type offset for fuser roll
temperature. Unsigned num-
ber in NVM table (displayed
on GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
10-060
Envelopes Offset
Media type offset for fuser roll
temperature. Unsigned num-
ber in NVM table (displayed
on GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
10-061
Labels Offset
Media type offset for fuser roll
temperature. Unsigned num-
ber in NVM table (displayed
on GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
10-063
Total Fsr Web
Total fuser web count.
Count
10-064
Transparency
Media type time delay for
delay
fuser roll temperature.
10-065
Cardstock delay
Media type time delay for
fuser roll temperature.
10-066
Envelopes delay
Media type time delay for
fuser roll temperature.
10-067
Labels delay
Media type time delay for
fuser roll temperature.
10-068
Tab stock delay
Media type time delay for
fuser roll temperature.
10-069
Cold Start Offset
Fuser cold start offset profile. 0 to 3
10-070
Cold Roll Offset
Fuser cold roll offset profile.
WorkCentre 5687 Family
Value
Default
Location NVM Name
0 to 25
15
10-071
0 to 30
15
10-072
10-074
10-075
10-102
0 to 30
15
10-122
10-123
10-124
Cycles
0
10-125
0 to 8 seconds 0
0 to 8 seconds 4
10-126
0 to 8 seconds 4
10-328
0 to 8 seconds 4
0 to 8 seconds 4
10-329
32/38/45/
55=0
10-330
65/75/87=2
0 to 11
32/38=1
45/55=6
65/75/87=8
August 2007
6-83
Table 9 NVM chain 10
NVM Description
Rough Stock Off-
Media type offset for fuser roll
set
temperature. Unsigned num-
ber in NVM table (displayed
on GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius.
Rough Stock
Media type time delay for
Delay
fuser roll temperature.
Rough Stk FRU
Rough Stock Fuser (TOS)
Enable
Type 256 FRU
Type 256 Fuser
Enable
Te PFs Toinv Mot
Inverter motor off stop posi-
Off Dup
tion (simplex).
Te PFs To Inv Mot
Time to turn off inverter motor
Off Dup
after TE leaves fuser
(duplex).
Fsr Range
Temperature range below
standby in which start print
can begin.
Te Inv Snr To Mot
Inverter motor off stop posi-
Of SmpS1
tion (simplex).
Te Inv Snr Inv Of
Time to turn off inverter motor
Dup Siz 1
after TE leaves inverter sen-
sor for sheets <185mm &
>216mm.
Web Advance
Web advance group banding
Group
select.
Standby Temp (2) Target temperature during
standby mode.
Run Temp (2)
Target temperature during
run mode.
Low Power Temp
Target temperature during
(2)
power save mode. The low
power simmer temperature is
determined by the Power
Save mode set in Tools.
Value
Default
0 to 25
15
0 to 8 seconds 4
Disable = 0
0
Enable = 1
Disable = 0
1
Enable = 1
0 to 800 ms
32/38=530
45/55=360
65/75/87=0
0 to 1200ms
32/38=740
45/55=510
65/75/87=0
10 to 30 deg C 32/38=30
45/55=10
65/75/87=28
0 to 800 ms
32/38=530
45/55=360
65/75/87=200
200 to 1200ms 32/38=740
45/55=510
65/75/87=295
1 = group 1
2
2 = group 2
3 = group 3
10 to 230 deg
32/38=190
C
45/55=195
65/75/87=208
100 to 230 deg
32/38=185
C
45/55=195
65/75/87=203
50 to 150 deg
32/38=85
C
45/55=95
65/75/87=135
General Procedures & Information