Siemens G130 List Manual page 1032

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r9984[0...4]
Data memory utilization TEC / Data mem util TEC
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
- [%]
Description:
Displays the data memory utilization as a result of Technology Extensions.
Index:
[0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Reserved
Dependency:
Refer to: F01068
Note:
TEC: Technology Extension
r9986[0...7]
DRIVE-CLiQ system load / DQ system load
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
- [%]
Description:
Displays the calculated DRIVE-CLiQ system utilization based on the existing target topology.
The values are only available in the "Initialization finished" state (r3988 = 800).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency:
Refer to: F01340
r9987[0...7]
DRIVE-CLiQ bandwidth load / DQ bandw load
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
- [%]
Description:
Displays the calculated DRIVE-CLiQ bandwidth utilization based on the existing target topology.
The values are only available in the "Initialization finished" state (r3988 = 800).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency:
Refer to: F01340
r9988[0...7]
DRIVE-CLiQ DPRAM load / DQ DPRAM load
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
- [%]
Description:
Displays the calculated DRIVE-CLiQ DPRAM load based on the existing target topology.
The values are not made available until the RUNUP READY (800) state is adopted (see p3988).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency:
Refer to: F01340
1032
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [%]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents