Job Card D/R A321 - Idc Computer - GE Senographe DS Manual

Hide thumbs Also See for Senographe DS:
Table of Contents

Advertisement

GE Healthcare
Revision 1

Job Card D/R A321 - IDC Computer

1
SUPPLIES
IDC Computer - Dione 4 or Dione 5, depending on your system level as follows:
-
Go to the Service Desktop home page (see
-
Consult Table 1 on page 63 in the section
Matrix on page
played on the Service Desktop home page, and by consulting Table 1 on page 63. The system
level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63.
-
If your system is at pre-Penduick level, order the Dione 4 (2375961)
-
If your system is at Penduick or above level, order the Dione 5 (5324091)
Floppy disk or CD-ROM with parameters for the currently installed image receptor
2
TOOLS
Standard Tool Kit
3
REQUIRED EFFORT
Personnel: 1 Field Engineer
Time: 90 minutes
4
SAFETY PRECAUTIONS
WARNING
Before beginning work, shut down the equipment correctly and switch OFF the
Senographe system hospital supply circuit breaker. Lock it in the OFF position and mark it
clearly with a warning sign to prevent others from applying power.
5
PREREQUISITES
Remove Control Station omega cover. See
Covers on page
503.
Backup the system configuration to a floppy diskette or a CD-R. See
Restore Procedure on page
all detector calibration procedures after the replacement.
JC-DR-A-321_DS.fm
63. Determine the system level from the ADS/IDC/Generator CPU versions dis-
771. If a current backup is not available, it will be necessary to carry out
Service Information and Procedures Class A 2385072-16-8EN
Launching the Service Desktop on page
Component FW/SW to ADS Version compatibility
Job Card PHY A040 - Remove/Reinstall Control Station
Page no. 1503
Senographe DS
Job Card D/R A321 - IDC Computer
Chapter 9
Job Card ELE A052 - Back-up/
120).
Chapter 9

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Senographe DS and is the answer not in the manual?

Questions and answers

Dr.Robert Mahmut
March 26, 2025

G.E.Essential l have recently bought What is the full weight.of the mamo Full weight of the console and other İtem's also measurements of each item with the main machine please All this Shipping Company required

1 comments:
Mr. Anderson
March 26, 2025

The GE Senographe DS mammography machine is shipped in three crates with the following dimensions and weights:

- Crate 1 (Gantry, Generator Cabinet, and ramp):
- Dimensions: 2066 mm (81.34 in) depth × 848 mm (33.39 in) width × 2292 mm (90.24 in) height
- Mass: 641 kg (1410.2 lbs)

- Crate 2 (Control Station):
- Dimensions: 1110 mm (43.70 in) depth × 770 mm (30.31 in) width × 1850 mm (72.83 in) height
- Mass: 210.5 kg (464.07 lbs) for truck transport (without side covers and lid)
- Mass: 223.5 kg (492.73 lbs) for plane/boat transport (with side covers and lid)

- Crate 3 (Detector):
- Dimensions: 872 mm (34.33 in) depth × 2270 mm (89.37 in) width × 260 mm (10.24 in) height
- Mass: 104.4 kg (229.68 lbs)

### Total Mass:
- For truck transport: 641 + 210.5 + 104.4 = 955.9 kg (2104.95 lbs)
- For plane/boat transport: 641 + 223.5 + 104.4 = 968.9 kg (2133.61 lbs)

These values include the gantry, generator cabinet, control station, detector, and all related components.

This answer is automatically generated

Table of Contents

Save PDF