Data Back-Up Via Machine Data - Siemens SINUMERIK 840D Simodrive 611 digital Startup Manual

Table of Contents

Advertisement

03/2006
11.5

Data back-up via machine data

Modified values,
MD 11210: UPLOAD_MD_CHANGES_ONLY (machine data back-up for modi-
backing up,
fied machine data only) can be used to define, when backing up machine and
setting data, whether all the data or just data that differs from the default setting
MD 11210
should be output via the V24 interface.
11210
UPLOAD_MD_CHANGES_ONL Y
MD Number
MD back-up of changed MD only
Standard default: 0
Change valid: immediately
Data type: BYTE
Meaning:
Selects a differential MD upload:
Bit 0 (LSB)
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Effectiveness: The change to the data takes effect when the upload for the next
area starts.
corresponds to ....
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
11.5 Data back-up via machine data
Min. input limit: 0
Protection level: 2/4
Valid from software version: 1 or 4
Effectiveness of the differential upload on TEA files
0: All data is output
1: Only machine data that differs from the default is output
(only applies to INITIAL_INI). If a value in data stored in the form of an
array is changed, the complete MD array is always output (e.g. MD 10000:
AXCONF_MACHAX_NAME_T AB).
Effectiveness of the differential upload on INI files
0: All data is output
1: Only MDs that have change compared to the compiled value
are output
Change to a field element
0: The complete array is output
1: Only the changed field elements of an arrays are output
R parameters (for INITIAL_INI only)
0: all R parameters are output
1: only R parameters not equal to zero are output
Frames (for INITIAL_INI only)
0: all frames are output
1: only frames that are not zero frames are output
Tool data, cutting parameters (for INITIAL_INI only)
0: all tool data is output
1: only tool data that is not equal to zero is output
Buffered system variables ($AC_MARKER[ ], $AC_PARAM[ ]
for INITIAL_INI only)
0: all system variables are output
1: only system variables that are not equal to zero are output
Synchronous action GUD (for INI files only)
0: all Syna GUDs are output
1: only Syna GUDs that are not equal to zero are output
11 Data Back-Up
Max. input limit: 1
Unit: –