Connecting Power Supply To And Grounding The Controller - ABB OmniCore C30 Product Manual

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

3.5.5 Connecting power supply to and grounding the controller

Location of power supply connection
xx1700001060
A
Location of grounding point
Product manual - OmniCore C30
3HAC060860-001 Revision: P
3.5.5 Connecting power supply to and grounding the controller
Note
How to manufacture a cable with connector is described in section
connector on page
92.
DANGER
A residual current device (RCD) must be installed.
A
Power inlet connector, X0
Note
According to IEC60204-1, the power-operated switch should be installed between
600 mm to 1,900 mm above the servicing level. The switch will be easily
accessible.
Note
The whole cabinet ground is connected to the X0.PE point.
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
Continues on next page
Fitting the
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents