Removing Cable Harness In Lower Arm And Armhouse - ABB IRB 2600 Series Product Manual

Hide thumbs Also See for IRB 2600 Series:
Table of Contents

Advertisement

4 Repair
4.3.1 Removing the complete cable harness
Continued
4
5
6
7

Removing cable harness in lower arm and armhouse

Use this procedure to remove the cable harness in the lower arm and armhouse.
Continues on next page
204
Action
Cut the cable straps securing the cable
harness to the frame and lower arm.
Prepare the end of the cable package in the
base with tape as shown in the figure.
Tip
In order to protect the connectors from
getting residual grease on the cable har-
ness, put some plastic over them prior to
pushing it through the hole in the frame.
Pull out the cable package through the hole
in the frame.
Note
Use caution when performing this proced-
ure in order not to damage cables or other
components!
Continue the removal of the cable package
from the lower arm and armhouse.
Tip
Before starting this procedure, first remove the cable harness in the base
Removing the complete cable harness on page 195
complete cable harness on page
© Copyright 2009-2018 ABB. All rights reserved.
Note
See the figure in:
Location of the cable harness on
page 196
F
E
xx1200000886
A Tape
B Connectors to SMB unit and Brake
release unit
C R1.CP/CS
D Air hose
E R1.MP
F R1.SMB (Connector bent and taped
upwards)
How to remove the cable package from
the lower arm and armhouse is described
in section:
Removing cable harness in lower
arm and armhouse on page 204
and frame
195.
Product manual - IRB 2600
A
D
C
B
Removing the
3HAC035504-001 Revision: Q

Advertisement