ENGINE-ELECTRICAL 6Y-22
(2) If voltage does not in crease significantly,
gen erator is d e fective. Check the fie ld wind­
ing, diode trio , r e c t ifie r bridge and stator
as c o v e re d in Section 6Y, Chassis Overhaul
Manual and re p a ir as required.
9. Turn o ff e le c tr ic a l loads, shut o ff engine and d is ­
connect a ll test equipment, if not p reviou sly done.
OVERCHARGED ENERGIZER
C O N D IT IO N CHECK
1. D eterm ine
E n e rg iz e r o r battery condition.
not valid if e n e rg iz e r is not good and fully charged.
2. Connect a voltm e te r fro m gen erator No. 2 term inal
to ground. If reading is zero , No. 2 lead circ u it is
open.
3. If E n e rg iz e r and No. 2 lead circ u it check good, but
an obvious overch arge condition exists as evidenced
by
e x c e s s iv e
E n e rg iz e r w ater usage, proceed as
follo w s:
a. Separate
end
fra m e s as covered in D elcotron
"D is a s s e m b ly "
section in the chassis overhaul
m anual.
b. Connect oh m m eter using low est range scale from
brush lead clip to end fram e as shown in Step 1,
F igu re 5D, then re v e r s e lead connections.
c. If both readings are ze ro , either the brush lead
clip is grounded o r regulator is defective.
d. A grounded brush lead clip can resu lt fro m o m is ­
sion of insulating washer (fig . 5D), om ission of
insulating
s le e v e o v e r screw , o r damaged in ­
sulating s le e v e .
R em ove screw to inspect sleeve.
If satisfa ctory,
rep lace regu lator as covered in
Section 6Y of the chassis overhaul manual.
GENERATOR OUTPUT TEST
To check the gen erator in a test stand, p roceed as
follo w s:
1. Make connections as shown in F igu re
leave
the
carbon
p ile
charged E n e rg ize r o r battery, and a 10 ohm r e s is to r
rated at six watts o r m ore between the gen erator
No. 1 term in al and the E n ergizer.
2. Slowly
in crease the gen erator speed and observe
the voltage.
3. If the voltage is uncontrolled with speed and in ­
cre a s e s above 16 v olts, check fo r a grounded brush
lead
clip
as
c o v e re d
CHARGED E N E R G IZ E R " , Step 3. If not grounded,
rep lace the regu lator.
T est is
6D, except
disconnected.
Use a fu lly
under
heading o f " O V E R ­
NOTE:
The E n erg izer must be fu lly charged
when making this check.
4. Connect the carbon p ile as shown.
5. Operate the generator at m oderate speed as required
and
adjust the carbon p ile as requ ired to obtain
maximum current output.
6. If output is within ten percent of rated output as
stamped
on
gen erator
7. If output is not within ten percent o f rated output,
ground gen erator fie ld (fig . 4D).
8. O perate
gen erator
at
carbon p ile as requ ired to obtain maximum output.
9. If output is within ten percent of rated output, r e ­
place regu lator as covered in "R e g u la to r R ep lace­
m ent" section.
10. If output is not within ten percen t of rated output,
check the fie ld winding, diode trio , r e c tifie r bridge
and stator as previou sly covered .
fram e, gen erator is good.
m oderate speed and adjust
CHEVROLET TRUCK SERVICE MANUAL