After a change in network settings, any devices in the system with a static IP address (e.g. RTSP
cameras) must be made compatible with the new address assigned to the system.
If a system contains MAX 1717/3x, MAX 1717/2x and/or VOG7 1761/3x video door phones to also
be connected to domestic networks via the second LAN connector, it is recommended to configure
the network for the IPerCom system with addresses of the type "10.x.y.z" and not the "192.168.x.y"
type usually used in common home networks. In general, pay particular attention not to have
devices with multiple network interfaces with subnets that can overlap.
If a static network setting is selected, it is also necessary to set the "IP Range Minimum", "IP Range
Maximum", "Network mask", "Default Gateway" and "DNS" parameters. These parameters are the
same as those presented in the "Custom Network Settings" section and their meaning is explained in
the following paragraph. In general, refer to a network administrator for the correct configuration
of the network itself.
If it is necessary to configure a system with Server 1060/1 where CallMe Manager support and static
IP addressing is required, follow the steps below:
• configure the PC with IPerCom Installer Tools in link local addressing;
• create the configuration only with Server 1060/1;
• set the static addressing mode on the system;
• connect the Server 1060/1 to the system;
• configure the PC with IPerCom Installer Tools with addressing compatible with the chosen static
addressing;
• verify that Server 1060/1 has a consistent address;
• configure the rest of the system.