APPENDIX D: IPerCom priority calls
Calls within an IPerCom system are shown in ascending order of priority:
auto-on;
intercom (call between two apartments);
call from Call Module/Entry Panel/Switchboard to apartment or from apartment to Switchboard;
emergency call.
Each call has two basic parameters (which can be set from the "System" tab of the configurator):
Maximum answer response time, after which the call ends (if the user does not answer). Default
setting: 60s.
guaranteed conversation time, after which the call can be interrupted by a call with the same
priority (higher priority calls can interrupt calls already in progress at any time). Default setting:
30s.
In the absence of interruptions, the conversation phase of a call lasts a maximum of 10 minutes.
Even an auto-insertion without interruptions has a maximum duration of 10 minutes (even if two-way
audio is activated within 10 minutes).
About call management, maximum answer response time, guaranteed conversation time and busy status in
the 2Voice system, please refer to the applicable system manual available on the website
Remember that if the Switchboard has already established a conversation with a 2Voice apartment station
and you want to call another 2Voice apartment station on the same column (stairs), having put the first
conversation on hold, this is not possible even after the guaranteed conversation time. You need to close
the first call and then make the second, otherwise an engaged message will continue to appear on the
Switchboard.