10.11 Factory reset of Entry Panel 1060/21
To perform a factory reset on an Entry Panel Ref. 1060/21, the following operations must be carried out in
sequence:
Switch the device off.
Press and hold the call key and the hall key.
Turn on the device.
Do not release the two buttons for at least 25 seconds.
During this -time, the following events can be observed in sequence on the device:
The camera LEDs will switch on and off.
The LED tags will flash 8 times.
The camera LEDs will switch on and off again.
The two buttons can now be released. After two seconds, factory reset is performed and the device
restarts.
The reset to factory settings can be carried out also via the Ipercom Installer Tools application
(button
of the Diagnostic tab).