Download Print this page

urmet domus IPerCom 3.1.0 System Technical Manual For The Installer page 258

Advertisement

The events that define the behaviour of the relay outputs can be divided into three groups listed below:
1. Events on device: outgoing call, auto-on, tamper alarm, coercion alarm, code activation; door
opening, gate opening, user recognition (following proximity key passage or door opener code
entry); these events can be set from the configuration page of the devices, i.e. Call Module, Entry
panel (1060/21-22-33-34-71-74-75), Modular Entry Panel with 1060/48, Key Reader.
2. Topological events: door opening, gate opening, incoming call (only for apartment stations), user
activation (on MAX, VOG
Apartment station T1 (key 1 of Miro door phone 1160/3 and video door phone 1761/6), user
activation - Apartment station T2 (key 2 of Miro door phone 1160/3 and video door phone 1761/6),
lift up, lift down, panic alarm, activation from switchboard. Except the last event, all others can
generally be set on a precise topological node of the system (i.e. at site, block, unit, floor, or
apartment level) and are then propagated on all apartment station contained in the topological
group of the node on which the activation will be created. If the activation has been set on an
apartment, it will only apply to that individual apartment. Switchboard activations, on the other
hand, concern only the Switchboard application and, more precisely, they are activation rules
created on the topological path of the application itself.
3. Automation events: events related to the configuration of the inputs of Relay Actuator 1060/84
(with firmware version 3.04 or higher).
Door and gate opening events on call devices activate one or more relay outputs only during the
call phase. The same events defined at topological level activate the relay outputs also outside the
call, by simply pressing the door and gate opening keys of apartment stations.
On the configurator the choice of the above events and the configuration of the corresponding relay
outputs can be carried out as follows.
258
7
5+
, VOG
, IPerCom Client and Basic video door phones), user activation -
MT124-032N

Advertisement

loading
Need help?

Need help?