7.1.10.2 Door/Gate Settings
The parameters are shown in the red rectangle in the following figure:
The meaning of the single items is shown in the following table:
Automatic Door Opening
Door/Gate opening on CCTV
Default Door Code Lenght
Key and Code mode
Automatic Call Closing After
Door Opening
Door Time (s)
Gate Time (s)
MT124-032N
Figure 482: "System" tab – "Door/Gate Settings"
If enabled, it allows the automatic opening of the doors during
the call phase. Default value: disabled. The function must also
be locally enabled on apartment station. Default value: not
enabled.
If disabled, it allows door/gate opening only and exclusively
during the call step. Default value: enabled (it is possible to
open door/gate also in auto-on).
Numeric door opener code length for residents and non-
residents. Default value: 6 (min 4, max 8).
If enabled, the access to the doors of the Call Module and
Modular Calling Station with 1060/48 occurs using both the
Proximity Key and the Door Code associated to the user.
Default value: disabled.
If enabled, if the door is opened during the unhook time or
during the conversation, the call is automatically closed 10s
after sending the door opening command. Similarly, if the
door is opened during auto on (with mono or bidirectional
audio), the same auto on is automatically closed 10s after
sending the door opening command. Default value: enabled.
Door opening time. Default value: 3s.
Gate opening time. Default value: 3s.
Table 17: meaning of the parameters in the "Door/Gate Settings" section
383