Main door settings
Used
Door Profile (#)
Main Door Name (#)
Door Opening Time (s) (#)
Door Forced Alarm (#)
Max Door Opening Time (s) (#)
Lock type (#)
Door Under Secret (#)
Remote Relay (#)
Remote Sensor (#)
MT124-032N
In this case, the item Yes enables the main door: the
following options are shown, marked with a hash mark (#).
The item No disables the main door. Default value: Yes.
It allows you to associate a previously created access profile
to the main door in question. In this case the door
parameters are automatically filled in (except the name).
Default value: customised (the parameters must be filled in
manually).
Name to assign to the main door.
Pulse duration on the control relay. Default value: 3 s.
If selected, if the door is forced, the current event sends an
alarm to the Switchboard.
Maximum door opening time beyond which a warning of
opened door is sent to the Switchboard.
It allows you to choose the type of lock installed on the main
door (see note at the end of the configuration section of the
Call Module
1060/12-13-17-18).
If selected, by pressing the door opener button (from an
indoor station) it is possible to activate the electric lock of
the outdoor station only when the caller is in conversation
or is waiting for a response. If not selected, the door can also
be opened outside the call phase from all the apartments
where the topological path detects the outdoor station.
Default value: selected.
It allows you to remotely control the relay that operates the
main door of the outdoor station. For further details, see
paragraph
"Remote relay functions, remote entrance hall
button and remote
sensor".
It allows you to remotely control the sensor that signals that
main door has been left open. For further details, see
paragraph
"Remote relay functions, remote entrance hall
button and remote
sensor".
Table 50: Main door settings
595
Need help?
Do you have a question about the IPerCom 3.1.0 and is the answer not in the manual?