C
3:
ONFIGURATION
calling stations of type Entry Panel 1060/21;
a maximum of 20 IPerCloud apartments.
If in the IPerCom system in IPerCloud mode it is instead required to have:
at least one calling station other than Modular Calling Station with 1060/48 or Entry Panel 1060/33-
34 or Entry Panel 1060/21,
or
several IPerCloud apartments greater than 200,
or
only Entry Panels 1060/33-34 with several IPerCloud apartments greater than 32,
or
only Entry Panels 1060/21 with several IPerCloud apartments greater than 20,
then it is necessary to have at least one 1060/1 Server in the system.
In a system with IPerCloud apartments without any calling station and with at least one Switchboard
1060/41, it is necessary to have at least a Server 1060/1.
The request for a 1060/1 Server may still be mandatory if the number of apartments or devices or
users (residents and not-residents) is greater than 1000.
In relation to the case of IPerCom systems in IPerCloud mode, if the presence of a 1060/1 Server is
requested, the configurator signals any lack of it in the configuration via a message when saving the
configuration itself (see paragraph
228
How to save the
Figure 252: message on configurator in the absence of Server 1060/1