10.6 Factory reset of the Modular Entry Panel with 1060/48
The factory reset of the Modular Entry Panel with 1060/48 can be done via the Outdoor Audio and Video IP
Station 1060/48 or via the Display Module 1168/1 (below):
Figure 695: Audio Video IP outdoor station (on the left) and Display Module (on the right)
10.6.1 Factory reset via the Outdoor Audio and Video IP Station 1060/48
There are 3 ways to perform a factory reset and they are listed below.
Mode 1: factory reset with reset button (Modular Entry Panel with 1060/48 ON)
Press the "RESET" button placed on the back of the Outdoor Audio and Video IP Station 1060/48 5 times
within 10 seconds (indicated in the figure with the red arrow). Each time the button is pressed feedback
tone is sent: the button must be pressed again immediately after the feedback tone. If the procedure has
been carried out correctly, the orange LEDs on the front panel will flash quickly for 6 times. After about 1
minute, the white LEDs illuminating name tags and buttons start flashing: this means that the factory reset
operation has been carried out correctly.