The following table shows the meaning of the fields for Key Reader 1060/45 e 1060/86.
General Settings
Name
MAC Address
IP Address
Device Code
Location
Door Profile
Door settings
Door Name
Door Time (s)
Forced Alarm
Time (*)
Max Door
Opening Time (s)
Door Under
Secret
Time Profile
Remote Relay
Remote Sensor
Hall Button Settings
Remote Button (#)
626
Name to assign to the Key Reader.
MAC address associated with the Key Reader.
IP address associated with the Key Reader. Field visible only if manual
network configuration is set in system parameters. Value that cannot be
changed.
Value that cannot be changed.
Position in the system topology: it is possible to move the device to
another node of the system by pressing the "Move" button.
This allows you to associate a previously created door profile with the
concerned door. In this case, the door parameters are automatically
compiled (besides the name). Default setting: Customised (parameters
must be compiled manually).
Name to assign to the door.
Pulse duration on the control relay. Default value: 3 s.
If selected, if the accessed is forced, the concerned event sends an alarm to
the Switchboard.
The maximum opening time of the door after which a notification is sent to
the Switchboard.
If not selected, pressing the door lock release button on an apartment
station, whose topological path intercepts the Key Reader, activates its
electric lock, even not during a call. If selected, the door can only be
opened by swiping a suitably registered key. Default setting: selected.
This allows you to associate a time profile with the door. Access will only be
valid within the selected time profile (except for residents of apartments,
whose topological path intercepts the key reader). Default setting: none.
It allows you to remotely control the relay that allows the Key Reader port
opening. For further details, see paragraph
entrance hall
button.
It allows you to remotely control the sensor that signals that main door has
been left open. For further details, see paragraph
remote entrance hall button and remote
Table 78:
General settings and door settings
It allows you to remotely control the entrance hall button
that opens the door of the Key Reader. For further details,
see paragraph
button and remote
Table 79: Hall button settings
Remote relay functions, remote
Remote relay functions,
sensor.
Remote relay functions, remote entrance hall
sensor.