6 Calibration
6.5.3 Calibrating axis 3 and axis 4
Continued
4
5
After calibration
1
582
Action
Check that the synchronization marks on axes 3
and 4 are aligned with each other.
Are they aligned within the tolerances?
If yes, the calibration is verified OK.
If no, redo the fine calibration procedure.
Update the revolution counters of axes 3 and 4.
Action
Write down the new system parameters on a new
label and stick on top of the calibration label on
the robot.
Note
The calibration status of axis 3 may be changed to Not updated after a system
reinstallation or warm restart. In this case, update the revolution counters for
axis 3 and axis 4 (axis 4 is coupled with axis 3). See
on page
560.
© Copyright 2023 ABB. All rights reserved.
Note
2
1
3
4
xx2300000573
See
Updating revolution counters
on page
560.
Note
Updating revolution counters
Product manual - IRB 930
3HAC086009-001 Revision: A