Refitting the SMB cover
1
2
3
Product manual - IRB 930
3HAC086009-001 Revision: A
Action
Reconnect the connectors.
SMB.P7
SMB.J1
SMB.J2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Refit the SMB cover assembly.
Secure the SMB cover to the base with the
screws.
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Note
xx2100000945
For robots with protection class
IP30 (option 3350-300)
Screws: Hex socket head cap
screw M4x10 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Tightening torque: 2.6 Nm
xx2300000489