5 Repair
5.6.7 Replacing the cable arm
Continued
Removing the cable arm
Use these procedures to remove the cable arm.
Preparations before removing the cable arm
Remove the robot from the wall or enough space.
1
2
3
Removing the process hub screws
1
2
3
Continues on next page
360
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
If there is no enough space for the maintenance
work, remove the robot from the wall and place it
on the maintenance bracket.
CAUTION
Do not lay down the robot during the transporta-
tion, always keep it straight.
If the robot lay down in any situation, the grease
may come out from gearbox.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safeguarded
space.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the screws locking the process hub.
Push the process hub to the outer arm.
© Copyright 2023 ABB. All rights reserved.
Note
Note
For robots with protection class
IP30
xx2300000487