Action
Insert the female head of the C1 cabling connector
to the bracket accordingly.
Tip
The mistake proofing measure has been applied
to the connectors, the connectors may be dam-
aged if excessive force is used.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
For robots with C1 cabling
Reconnect the connector.
•
R2.C1
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same L-shaped connector.
For robots with C2 cabling
Reconnect the connector.
•
R1.C2
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same L-shaped connector.
Secure the C2 cabling to the C2 bracket with the
cable straps.
Reconnect the air hoses in a cross pattern with
the L-shaped connectors.
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same Y-shaped connector.
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Note
xx2300000544
xx2300000542
Continues on next page
211