ABB IRB 930 Product Manual page 298

Table of Contents

Advertisement

5 Repair
5.6.3 Replacing the pulley on the ball screw lower position
Continued
2
3
Removing the cover of the outer arm
1
2
Releasing the axis-3 timing belt
1
Continues on next page
298
Action
Remove the screws locking the process hub.
Push the process hub to the outer arm.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the screws on the cover of the outer arm
and remove the cover.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2023 ABB. All rights reserved.
Note
For robots with protection class
IP30
xx2300000487
Note
For robots with protection class
IP30
xx2300000488
Note
Product manual - IRB 930
3HAC086009-001 Revision: A

Advertisement