ABB IRB 930 Product Manual page 467

Table of Contents

Advertisement

3
Disconnecting the connectors for axis-4 motor
1
2
Removing the outer arm cable ferrule and bracket
1
Product manual - IRB 930
3HAC086009-001 Revision: A
Action
Snap loose and remove the female head of the
connectors from the bracket.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
Action
Disconnect the axis-4 motor connectors.
R2.MP4
R2.FB4
Snap loose and remove the female head of the
connectors from the bracket.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2023 ABB. All rights reserved.
5.7.4 Replacing the axis-4 motor sub-assembly
Note
xx2300000494
Note
xx2300000492
xx2300000495
Note
5 Repair
Continued
Continues on next page