Disconnecting the SMB cabling
1
2
3
4
Product manual - IRB 930
3HAC086009-001 Revision: A
Action
Remove the screws on the SMB cover to the base.
Pull the SMB cover with the SMB unit assembly
out together.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Cut the strips.
Disconnect the connectors.
SMB.P7
SMB.J1
SMB.J2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.