Data backup
15.7 Serial interface (V24 / RS232)
15.7.2

Setting interface parameters

Procedure
RS-232-C settings
Parameter
Protocol
Transfer
Baud rate
288
1.
Select the "Start-up" operating area.
2.
Press the "System data" softkey.
3.
Press the ">>" and "Archive" softkeys.
4.
Select the "RS-232-C settings" softkey.
The "Interface: RS-232-C" window is opened and the interface
settings are displayed.
5.
Press the "Details" softkey if you wish to view and process
additional settings for the interface.
Meaning
The following protocol is supported for transfer via the RS-232-C:
RTS/CTS
It is also possible to use a secure protocol for data transfer (ZMODEM
protocol).
Normal (default setting)
Secure
For the selected interface, secure data transfer is set in conjunction
with handshake RTS/CTS.
Transfer rate: Transfer rates of up to 115 kbaud can be selected. The
baud rate that can be used depends on the connected device, the
cable length and the general electrical conditions.
110
....
19200 (default setting)
...
115200
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1