Safety Integrated
21.2 Safety Integrated diagnostics
References
The functions are described in: Function Manual, Safety Integrated
Procedure
...
21.2.6

Safety Integrated fail-safe I/O

Fail-safe I/O modules ("fail-safe modules")
The "SI I/O" display provides a summary of the configuration and status of the PROFIsafe
I/O. The following signals are displayed:
● Fail-safe master address
● Parameterized PROFIsafe cycle time
● Maximum occurring PROFIsafe cycle time
● Modular PROFIsafe I/O interface
● Number of active I/O modules
● Number of passive I/O modules
444
1.
Select the "Diagnostics" operating area.
2.
Press the menu forward key and the "Safety" softkey.
3.
Press the "SI status" softkey.
The "SI status" window is opened.
4.
Press the "Display drive status" softkey to display the status of safe
drives.
5.
Press the "Drive +" or "Drive -" softkey.
The parameters are displayed for the next or previous drive object.
- OR -
6.
Press the "Drive selection" softkey and in the drop-down list that
appears, directly select the desired drive object.
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1