Components that cannot be accessed
Input rights
Operator panels, which have input rights, have a green background.
Detailed view
You have the option to display the following information about a selected component.
TCU
● IP address
● SW version
● MCP index from the configuration
● TCU index from the configuration
● DNS name
● Resolution
MCP
● IP address
● DNS name
● MCP index from the configuration
● MCP index requested from HMI
● MCP index requested from PLC
Procedure
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
If a component cannot be accessed, then it is marked using this symbol.
1.
Select the "Diagnostics" operating area.
2.
Press the menu forward key and the "Bus TCP/IP" softkey.
3.
Press the "TCP/IP diagnostics" softkey.
The "TCP/IP Diagnostics" window is opened and displays the current
availability of the network connections.
4.
Position the cursor on the component for which you wish to display the
detailed information.
Service and diagnostics
18.11 Station-related network diagnostics
353