SINUMERIK
SINUMERIK 840Dsl/828D
SINUMERIK Integrate for
Engineering Access MyMachine /
OPC UA
Configuration Manual
Valid for:
OPC UA server
04/2018
6FC5397-1DP41-0BA0
Version 2.0 SP1
Preface
Introduction
Safety notes
Setting up of OPC UA server
User administration
Functionality
Diagnostics
Update of OPC UA Server
Technical data
Trouble shooting
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SINUMERIK 840Dsl

  • Page 1 Preface Introduction Safety notes SINUMERIK Setting up of OPC UA server SINUMERIK 840Dsl/828D SINUMERIK Integrate for User administration Engineering Access MyMachine / OPC UA Functionality Configuration Manual Diagnostics Update of OPC UA Server Technical data Trouble shooting Valid for: OPC UA server Version 2.0 SP1...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Siemens' content, and adapt it for your own machine documentation. Training At the following address (http://www.siemens.com/sitrain), you can find information about SITRAIN (Siemens training on products, systems and solutions for automation and drives). FAQs You can find Frequently Asked Questions in the Service&Support pages under Product Support (https://support.industry.siemens.com/cs/de/en/ps/faq).
  • Page 4 Technical Support Country-specific telephone numbers for technical support are provided in the Internet at the following address (https://support.industry.siemens.com/cs/sc/2090/) in the "Contact" area. SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 5: Table Of Contents

    Table of contents Preface.................................3 Introduction..............................7 General description........................7 1.1.1 SINUMERIK OPC UA server....................7 Features...........................7 System setup...........................9 Reference to OPC UA specification..................9 Safety notes..............................11 Fundamental safety instructions....................11 2.1.1 General safety instructions.....................11 2.1.2 Warranty and liability for application examples..............11 2.1.3 Industrial security........................12 OPC UA security notes......................13 Setting up of OPC UA server........................15 Prerequisites..........................15 Option OPC UA........................16...
  • Page 6 Table of contents Alarms............................47 5.4.1 Overview..........................47 5.4.2 Subscribe / unsubscribe to alarms ..................48 5.4.3 SINUMERIK Alarm object......................49 5.4.3.1 Description..........................49 5.4.3.2 OPC UA event messages and alarms...................49 5.4.4 Sequence description of alarms.....................54 File system..........................54 5.5.1 Overview..........................54 5.5.2 File access rights........................55 5.5.3 Standard file system support....................58 Diagnostics..............................61 Overview ..........................61...
  • Page 7: Introduction

    Introduction General description Uniform standard for data exchange "Industrie 4.0" stands for the intensive utilization, evaluation and analysis of data from the production in IT systems of the enterprise level. PLC programs today already record a wide range of data at the production and process level (pressure values, temperatures and counter readings) and make them available to systems at the enterprise level, for example, to increase the product quality.
  • Page 8 Introduction 1.2 Features ● Support for File and Folder Objects ● Event based provision of SINUMERIK alarms and messages from HMI, NC and PLC (see chapter Alarms (Page 47)) Security settings The server provides the possibility to communicate in an unencrypted or encrypted way. The following options are possible: ●...
  • Page 9: System Setup

    Introduction 1.4 Reference to OPC UA specification System setup Accessibility of the server The accessibility of the server varies in the particular SINUMERIK systems. The following table shows the dependencies of the SINUMERIK systems: SINUMERIK Accessibility systems SINUMERIK After successful licensing and activation the OPC UA server is accessible via the X130 interface. 828D SINUMERIK The OPC UA server needs SINUMERIK Operate and runs on the same place as SINUMERIK Operate.
  • Page 10 Introduction 1.4 Reference to OPC UA specification SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 11: Safety Notes

    Safety notes Fundamental safety instructions 2.1.1 General safety instructions WARNING Danger to life if the safety instructions and residual risks are not observed If the safety instructions and residual risks in the associated hardware documentation are not observed, accidents involving severe injuries or death can occur. ●...
  • Page 12: Industrial Security

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
  • Page 13: Opc Ua Security Notes

    Safety notes 2.2 OPC UA security notes WARNING Unsafe operating states resulting from software manipulation Software manipulations (e.g. viruses, trojans, malware or worms) can cause unsafe operating states in your system that may lead to death, serious injury, and property damage. ●...
  • Page 14 Safety notes 2.2 OPC UA security notes SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 15: Setting Up Of Opc Ua Server

    You will find further information on the Defense-in-Depth concept, suitable protective measures and Industrial Security in general in the Configuration Manual Industrial Security (https://support.industry.siemens.com/cs/de/en/view/108862708). Prerequisites ● OPC UA requires SINUMERIK Operate. ● OPC UA requires an OPC UA license (6FC5800-0AP67-0YBO).
  • Page 16: Option Opc Ua

    Setting up of OPC UA server 3.3 Commissioning Option OPC UA Setting the option 1. Set the "Access MyMachine /OPC UA" option via the "Startup > Licenses" operating area. Figure 3-1 Setting the option Commissioning Checking the HMI time Make sure that the HMI time is set correctly, since this is a prerequisite for encrypted communication.
  • Page 17 Setting up of OPC UA server 3.3 Commissioning Executing the OPC UA configuration dialog 1. Start the OPC UA configuration dialog via the operating area "Startup > Network". 2. Press the "OPC UA" softkey. SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 18 Setting up of OPC UA server 3.3 Commissioning 3. Press the "Setup" softkey. Then press the "Change" softkey. The Settings dialog will appear. Make the necessary settings for connection, authentication and activation. Figure 3-2 Settings of OPC UA Server (with changes) SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 19 Setting up of OPC UA server 3.3 Commissioning Group Setting Description Connection set‐ IP address The IPv4 address of the company network interface, tings since this is the primary server interface. This is deter‐ mined automatically. Even if there is only one address stated in this dialog, the OPC UA server is available at the following interfaces: SINUMERIK 828D -X127...
  • Page 20 Setting up of OPC UA server 3.3 Commissioning Group Setting Description Authentication Admin User User name of the administrator. The administrator can add or delete users and assign or delete user authoriza‐ tions. Password Password of the administrator. Confirm Password Enter the password again for confirmation.
  • Page 21 Setting up of OPC UA server 3.3 Commissioning Note Assigning secure passwords Observe the following rules when creating new passwords: ● When assigning new passwords, ensure that you do not assign passwords that can be guessed, e.g. simple words, key combinations that can be easily guessed, etc. ●...
  • Page 22: Certificate Handling

    Setting up of OPC UA server 3.4 Certificate handling 4. Then choose "OK". If you enter a port for the first time, you will receive a safety note. Figure 3-3 Security message for opening the TCP port Note Port opening on IPC On first startup of OPC UA server a windows message will appear, asking the user to confirm the opening of the port.
  • Page 23 Press the softkey “System data”. In the files and folders tree navigate to: ● Embedded systems (NCU 840Dsl / 828D): "System CF Card/addon/sinumerik/hmi/opcua/pki/rejected" ● PCU system: "System harddisk/C: System/ProgramData/Siemens/MotionControl/addon/sinumerik/hmi/ opcua/pki/rejected" Select the rejected certificate. Press softkey “Cut”. Navigate to folder “trusted/certs”. Press softkey “Paste”.
  • Page 24: Testing The Connection

    ● Connection with the security policy "Basic128Rsa15" respectively "Basic256" and the security mode "SignAndEncrypt" SIEMENS always recommends setting up a connection with security, as only in this way the confidentiality of the data transmitted can be ensured. SINUMERIK Integrate for Engineering Access MyMachine / OPC UA...
  • Page 25 Setting up of OPC UA server 3.5 Testing the connection Installation The "Sample Applications" additionally install a service with the name "OPC UA Local Discovery Server". If you want to locally test the OPC UA connection, i.e. an installation directly on the PCU 50, you must deactivate this service.
  • Page 26 Setting up of OPC UA server 3.5 Testing the connection Procedure 1. Start the OPC UA "Sample client". Figure 3-5 Sample Client main window 2. Select the "New" entry from the drop-down list. The "Discover Servers" window opens. 3. Now enter the IPv4 address of the target system and click the "Discover" button. Figure 3-6 Discover servers 4.
  • Page 27 Setting up of OPC UA server 3.5 Testing the connection 5. Return to the main window and click the "Connect" button. 6. To establish a simple connection without security, configure the following settings. After clicking "OK", enter the administrator user assigned when OPC UA was set up and the administrator password.
  • Page 28 Setting up of OPC UA server 3.5 Testing the connection 7. Confirm the prompt asking if you want to trust the transferred certificate with "Yes". Figure 3-9 Certificate The connection to the SINUMERIK OPC UA server is now established and the available address space is displayed.
  • Page 29 Setting up of OPC UA server 3.5 Testing the connection – E.g. read, write, setup monitoring Figure 3-11 NodeID "Sinumerik > Channel > Parameter > R" – The attributes of a NodeID can be queried via the entry "View Attributes". One of these attributes is the "Value", which provides the corresponding value of R1.
  • Page 30 Setting up of OPC UA server 3.5 Testing the connection SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 31: User Administration

    User administration Overview The admin can add/delete users and rights via OPC UA methods provided by the server. Therefore a connection with a generic client must be established, using the admin credentials. Users and rights can then be assigned using the following OPC UA server methods: ●...
  • Page 32: User Management

    User administration 4.2 User management User management A new user created with the "AddUser" function has no rights at all. The user administrator has the responsibility for the user management and the associated rights. All users must use a secure password. Table 4-1 Methods for user administration Method...
  • Page 33: Rights Management

    User administration 4.3 Rights management Rights management After setting up the OPC UA components, the administrator user has read access to all data ("SinuReadAll") but no write access. These rights must be set explicitly . Table 4-2 Methods for user administration Method Description GetMyAccessRights...
  • Page 34: List Of Rights

    User administration 4.4 List of rights List of rights Below is the list of rights a user is assigned: Table 4-3 List of rights Method Description GiveUserAccess Sets the specified access rights for a user. The rights below can be combined in any combi‐ nation.
  • Page 35: Functionality

    Functionality Overview Overview The SINUMERIK OPC UA server provides the possibility to communicate with SINUMERIK via OPC UA. The following functionalities of the OPC UA specification are supported by the server: ● Data Access: Read, write and subscribe to SINUMERIK variables (NC, PLC) ●...
  • Page 36 Functionality 5.2 Address space model Observe the following while browsing: ● In the address space of the NC, the displayed variables always represent only the first parameter of the corresponding unit. Example: The R parameters can be found under "Sinumerik > Channel > Parameter > R". The corresponding identifier is called "/Channel/Parameter/R", which is finally mapped to "/ Channel/Parameter/R[u1, 1]".
  • Page 37 Functionality 5.2 Address space model Figure 5-1 Excerpt from browsing the OPC UA data access interface SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 38: Variable Access

    The variable paths for NC access are stored in the address space of the SINUMERIK Operate OPC UA server. You can obtain additional information from the List Manual for 840D sl and 828D "NC variables and interface signals" (https://support.industry.siemens.com/cs/de/de/view/109748365/en). Figure 5-2 Identifier for R parameter The displayed NC variables always represent only the first parameter of the corresponding NC data area (channel, TO area, mode group).
  • Page 39: Variable Paths For Gud Access Operations

    Functionality 5.3 Variable access The R parameters are found under the identifier "/Channel/Parameter/R", which is eventually mapped to "/Channel/Parameter/R[u1, 1]". If you want to access other parameters, you must correspondingly extend the identifier, e.g. "/Channel/Parameter/R[u2, 56]". Table 5-1 Examples of variable paths (NC access operations) Variable path Description /Channel/Parameter/R[u1,10]...
  • Page 40: Variable Paths For Plc Access Operations

    Functionality 5.3 Variable access Access is performed as follows: ABC[0,0] → /NC/_N_CH_GD3_ACX/ABC[u1, 1] ABC[0.1] → /NC/_N_CH_GD3_ACX/ABC[u1, 2] ABC[0.2] → /NC/_N_CH_GD3_ACX/ABC[u1, 3] ABC[1.0] → /NC/_N_CH_GD3_ACX/ABC[u1, 4] ABC[1.1] → /NC/_N_CH_GD3_ACX/ABC[u1, 5] ABC[1.2] → /NC/_N_CH_GD3_ACX/ABC[u1, 6] ABC[2.0] → /NC/_N_CH_GD3_ACX/ABC[u1, 7] ABC[2.1] → /NC/_N_CH_GD3_ACX/ABC[u1, 8] ABC[2.2] →...
  • Page 41 Functionality 5.3 Variable access Area Address (IEC) Permissible data types OPC UA data type Output image DWORD, UInt32 DINT, Int32 REAL Double Data block DBz.DBXx.y BOOL Boolean Data block DBz.DBBx BYTE, CHAR, UInt32 STRING String Data block DBz.DBWx WORD, CHAR, UInt32 Int32 Data block...
  • Page 42: Variable Paths For Machine And Setting Data

    Functionality 5.3 Variable access Variable path Description /Plc/DB8.DBB2:STRING UTF8 string beginning at byte offset 2 in data block 8 /Plc/DB8.DBW2:[10] Array of 10 words beginning at byte offset 2 in data block 8 /Plc/DB100.DBB1 Byte at byte offset 1 in data block 100 /Plc/DB2.DBD0:REAL[10] Array of 10 double words (32-bit) beginning at byte offset 0 in data block 2, which are formatted as a floating-point number...
  • Page 43 Functionality 5.3 Variable access /Random@<NCUName><NodeId> Examples of variable paths (1:N constellation) Examples of variable paths (1:N constellation) Variable path Description /Random@NCU_1/Channel/Parameter/R[u1,10] R parameter 10 in channel 1 of NCU_1R parameter 10 in channel 1 of NCU_2 /Random@NCU_2/Channel/Parameter/R[u1,10] /Random@NCU_1/Plc/DB123.DBB0 Byte at byte offset 0 in data block 123 of NCU_1 Note The NCU names are listed in the "MMC.ini"...
  • Page 44: Reference Of Opc Ua Variables

    5.3.6 Reference of OPC UA variables For more information on variable documentation, refer: NC variables and interface signals (https://support.industry.siemens.com/cs/de/de/view/109748365/en) Example 1: Finding an OPC UA variable in the variable documentation You want to find the variable "opMode" in folder "/Bag/State".
  • Page 45: Monitored Items

    Functionality 5.3 Variable access 1. At the beginning of each chapter for variable sections, you find the information "OEM-MMC: LinkItem“ specifying "/ToolCompensation/“. 2. Refer to the document and search for "ChannelCompensation" and then navigate manually to the requested parameter "cuttEdgeParam". Example 3: Finding a variable from documentation on OPC UA client You want to find the variable "cuttEdgeParam"...
  • Page 46 Functionality 5.3 Variable access A subscription consists of at least one monitored item, that has to be created within the context of a session and can be transferred to another session. To create a session, a secure channel between the client and the server has to be established. There are two different types of “changes”...
  • Page 47: Alarms

    Functionality 5.4 Alarms Alarms 5.4.1 Overview Any OPC UA client supporting Alarms & Conditions connected to the SINUMERIK OPC UA server can subscribe to alarms to get the notifications of alarms. All OPC UA Clients that have subscribed for SINUMERIK alarms will be provided with an alarm as soon as it becomes active.
  • Page 48: Subscribe / Unsubscribe To Alarms

    Functionality 5.4 Alarms 5.4.2 Subscribe / unsubscribe to alarms Subscribe to alarms The SINUMERIK Alarm Event object is connected to the SINUMERIK node. To receive the alarms, an event subscription must be placed at the SINUMERIK node. The following example describes how to receive the alarms using the OPC UA Foundation Client: 1.
  • Page 49: Sinumerik Alarm Object

    Functionality 5.4 Alarms Figure 5-6 Alarm List Unsubscribe to alarms 1. Click "Conditions > Set Area Filter…". The "Select Area" window appears. 2. Right click on "Sinumerik" and select "Remove Monitored Item" to unsubscribe the server from the Quickstart Alarm Condition Client. 5.4.3 SINUMERIK Alarm object 5.4.3.1...
  • Page 50 Functionality 5.4 Alarms An alarm is composed of various nested or parallel state machines. Monitoring can generally be enabled or disabled. If monitoring is enabled, the alarm can be active or otherwise inactive. Acknowledgment, confirm and comments of alarms is currently not supported. The basic type for all condition objects is the condition type.
  • Page 51 Functionality 5.4 Alarms Attributes of BaseEventType Attribute Data type Mapping with respect to SINU‐ Description MERIK EventId String Unique node id generated from EventId is generated by the Server to SINUMERIK system. uniquely identify a particular Event Notifi‐ cation. The EventId shall always be returned as value and the Server is not allowed to re‐...
  • Page 52 Functionality 5.4 Alarms Severity of Alarms SINUMERIK systems use three severity levels (e.g. Information, Warning and Error). The table below shows the values at SINUMERIK system and its mapping in OpcUa Server/Client. Severity Level SINUMERIK System OpcUa Server/Client Information Warning 2-999 Error 1000...
  • Page 53 Functionality 5.4 Alarms Attribute Data type Mapping with respect to SINU‐ Description MERIK AddComment Not supported Not supported and the result code should return Bad_MethodInvalid. ConditionRe‐ None When the method is called up, an event freshMethod with the current state is triggered for the calling client for all conditions.
  • Page 54: Sequence Description Of Alarms

    Functionality 5.5 File system 5.4.4 Sequence description of alarms The OPC UA Server automatically sends an object of the "CNCAlarmtype" to the OPC UA Client containing the single alarm which has just been triggered. The OPC UA Server automatically resends an object of the "CNCAlarmtype" with the same content as when the corresponding alarm was triggered, except a change in the status.
  • Page 55: File Access Rights

    Functionality 5.5 File system Figure 5-8 The file system 5.5.2 File access rights The OPC UA server allows the OPC UA client to support the transfer of files between the client and the server. SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 56 Functionality 5.5 File system The two methods CopyFileToServer and CopyFileFromServer and also standard file system methods need the following access rights: ● FsRead ● FsWrite As a user, you will require user access rights to access these files from the server. The access rights are provided using the "GiveUserAccess"...
  • Page 57 Functionality 5.5 File system Figure 5-9 Standard Method SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 58: Standard File System Support

    Functionality 5.5 File system 5.5.3 Standard file system support Standard methods The SINUMERIK OPC UA server supports the "FileType"/"FolderType" as described in the OPC UA Specification Part 5, which allows manipulating files and folders via OPC UA. The folders, "Part Programs", "Sub Programs" and "Work Pieces" are of the "FileType"/"FolderType"...
  • Page 59 Functionality 5.5 File system "CreateFile" method is called, is the "parent" node of the new file node. For specific information for the described methods, check the Typedefinition in the OPC UA Specification Part 5. Note No multiple extensions supported The methods "CreateFile","CopyFileToServer", "CopyFileFromServer" and "MoveOrCopy" will not support files with multiple extensions (i.e.
  • Page 60 Functionality 5.5 File system 1. CopyFileFromServer: – Allows copying file from SINUMERIK OPC UA server to client location. – The user shall provide the name of the file with full path to be copied. – On completion of the file transfer, an appropriate message will be displayed. Type Data type Argument...
  • Page 61: Diagnostics

    Diagnostics Overview Overview The OPC UA server offers a variety of diagnostics information, as described in the OPC UA Standard Part 5 - "Information Modell", Chapter 6. This diagnostics information can be found under the Server Node: Figure 6-1 Diagnostics Information - Server Node Diagnostics screen Requirement Note...
  • Page 62 Diagnostics 6.2 Diagnostics screen Diagnostics screen Additional to the server diagnostic information available via OPC UA, there is a SINUMERIK Operate screen, which shows the actual status of the OPC UA server. To open the diagnostics screen, select the operating area "Startup > Network" in SINUMERIK Operate, then press the "OPC UA"...
  • Page 63 Diagnostics 6.2 Diagnostics screen Value Description Further explanation Connected cli‐ Clients which are connected to the server ents Example: ● MD1EXMQC: remote PC of the client ● SiemensAG:OpcUaTestsApp: URN of the application of the remote PC ● 10788… Session ID ●...
  • Page 64: Opc Ua Server Version

    Diagnostics 6.3 OPC UA server version OPC UA server version OPC UA server version OPC UA server version and OPC UA dialog version information can be found in SINUMERIK OPERATE version screen. 1. Open SINUMERIK OPERATE and choose operating area "Diagnostics". Press the softkey "Version".
  • Page 65 Diagnostics 6.3 OPC UA server version Figure 6-4 Version data / system extensions The OPC UA entry is found. 3. Select the entry and press "Details" again to show more detailed information on OPC UA components. SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 66 Diagnostics 6.3 OPC UA server version SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 67: Update Of Opc Ua Server

    This version of OPC UA server is supported by SINUMERIK 840D sl and SINUMERIK 828D. An update process is possible with SINUMERIK software version ≥ V4.7. SINUMERIK Integrate Create MyConfig (CMC) The necessary update (CMC) file can be provided by your regional SIEMENS office. Installation of OPC UA server OPC UA - Server update The installation procedure of the OPC UA server will vary depending whether a PCU or a PPU/ NCU is being used.
  • Page 68: Compatibility

    In previous versions additionally added read rights have not been deleted with removing “SinuReadAll”. Same applies to “SinuWriteAll”. Note If you face any other compatibility issues or for further details, refer to hotline (https:// support.industry.siemens.com/cs/sc/2090/). SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 69: Technical Data

    Technical data Technical data Description Value Number of sessions 828D 840 D sl Number of subscriptions 828D 840D sl Maximum samples / second 828D 500 1/s 840D sl 1000 1/s Min. sampling interval 100 ms Sampling intervals {100, 250, 500, 1000, 2500, 5000} ms Min.
  • Page 70 Technical data SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 71: Trouble Shooting

    This may cause incorrect functioning of the OPC UA configuration dialog in software versions < 4.8 SP2. Please contact your regional SIEMENS office or the technical support (https://support.industry.siemens.com/cs/sc/2090/). Reference to OPC UA error code You can find all relevant information on error codes at Github (https://github.com/...
  • Page 72 Trouble shooting 9.1 Reference to OPC UA error code SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...
  • Page 73: Index

    Index Accessibility, 9 License, 16 AddCertificateUser, 32 AddUser, 32 Application scenario, 9 Max. lifetime interval (LifeTime Count), 69 Max. monitored items queue size (Subscription Queue size), 69 Browsing, 35 Max. number of users, 69 Maximum samples / second, 69 Min. publishing interval, 69 Min.
  • Page 74 Index User administration, 8 Variable paths, 38 SINUMERIK Integrate for Engineering Access MyMachine / OPC UA Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0...