Siemens SINUMERIK 840D sl Commissioning Manual page 221

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

5. Link the contents of the <context> <name> tags with the contents of the <message>
6. If you include an additional NCK alarm, copy the range from <Alarms> to </Alarms> and
7. If you include an additional alarm from another number range (e.g. PLC alarm), copy the
Note
A dedicated link must be created for each standard alarm for which the text is to be replaced.
Example
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE SlAeAlarmAttributes>
<SlAeAlarmAttributes Version="01.00.00.00">
<Types>
</Types>
<Sources>
</Sources>
</SlAeAlarmAttributes>
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
<source> tags from your alarm text file.
– <context> <name> = the context name that you assigned
– <message> <source> = the number of the alarm whose text is to be replaced.
E.g. enter the following link in the alarm attribute file: <MSGTEXT>myNckAlarms Ι
10000</MSGTEXT>
Make sure that the context name and the alarm number are separated by the pipe
character "Ι".
adapt the alarm number.
range <Sources> to </Sources> and then adapt the SourceID and SourceURL as well as
the alarm number.
You can take the corresponding SourceID and SourceURL from the table in Section
Range of alarms (Page 217).
<Type TypeName="Condition" TypeID="32">
<Category Version="1.0" CatID="1">
<CatDescr>Alarms of the Sinumerik 810/840 D(i).</CatDescr>
<Attributes>
</Attributes>
</Category>
</Type>
<Source CatLink="1" SourceID="0" SourceURL="/NCK">
<Alarms>
<Alarm AlarmID="10000">
<MSGTEXT>myNckAlarms|10000/NCK</MSGTEXT>
</Alarm>
</Alarms>
</Source>
13.2 Configuring alarm and message texts via alarm text files
Configuring alarms
215

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents