Siemens SINUMERIK 840D sl Commissioning Manual page 839

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

After the entry of the remote file system, you can also specify the required directory
('MOUNTPOINT') in which the remote files will become visible locally. This should be an
empty directory to which you have write access. If MOUNTPOINT is omitted, 'sc' itself
generates a suitable directory. The name is /tmp/drvNN (numbered consecutively), and is
displayed when the connection is successful.
The option "-ro" connects the remote file system in read-only mode, which means that you
can only read and do not have write access. This can be useful if you want to exclude
changes that originate from the controller, or if the server only allows read-only connections.
As explained above, an SMB file system is connected as the specified user. To prevent a
third user from executing file operations on the controller in the name of the connected user,
the local directory can normally only be accessed by the latter (and all members of the same
group).
However, if you do want to make the remote directory available to further local users, you
can use the option "-public" to make the MOUNTPOINT belong to the "operator" group, and
this access is therefore guaranteed.
2.5.6
Disable
Description
Syntax:
Alternative names:
Authorization level:
The "sc disable" command switches the specified subsystems off. These subsystems are
then not loaded again at the next restart. You can also switch several subsystems off with a
single "disable" command. "hmi", "nck" or any other subsystem names can be used for the
subsystems.
Note
The "sc disable" command acts on the parameters in the file basesys.ini, which is in the
following directory: card/user/system/etc/basesys.ini
"sc disable IPAlias" deactivates the second alias IP address for the X120 network interface.
See also
Parameters "InternalIP_Alias" and "InternalNetMask_Alias" in the "basesys.ini" file.
NCU operating system (IM7)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
sc disable hmi|nck|SUBSYSTEM ...
sc disable DHCPSvr -INTERFACE
sc disable DHCPSync [-X120]
sc disable IPAlias [-X120]
sc disable usb [-MINUTES] all | HOSTS
---
service
Configuring the system
2.5 Description of the actions
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents