Siemens SINUMERIK 840D sl Commissioning Manual page 297

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Restrictions
● The leases files are not saved:
● A configuration in the system network must be based on the DNS name rather than IP
Basic procedure
● Backup of network settings
● Importing network settings
NCU
Only the NCU settings are saved with the HMI on the NCU. The following data is backed up:
● /user/system/etc/basesys.ini
● /user/common/tcu (complete directory)
The network settings of an NCU can be backed up and read only from an HMI on the
PC/PG. This means the NC address in mmc.ini on the PC/PG is always 192.168.215.1.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
– /system/etc/udhcpd-eth0.leases
– /system/etc/udhcpd-ibn0.leases
addresses.
After activation, the network settings can also be backed up when a commissioning
archive is created when a check mark is set, see Creating a start-up archive (Page 278).
The saved archives can be imported in the same manner as a commissioning archive,
see Reading-in a start-up archive (Page 280).
Note
Importing network settings for replacement components
Disconnect the replacement components from the system network before you import the
saved network settings.
Data backup
15.9 Network settings
291

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents