Procedure
18.15
PROFIBUS/PROFINET and AS-i bus diagnostics
18.15.1
PROFIBUS/PROFINET
With the PROFIBUS/PROFINET diagnostics, you obtain a quick overview from which, when
required, you can call status and detailed information for external DP master systems and
PROFINET IO systems.
Precondition for detailed diagnostics
When using HMI PRO RT, the diagnostics can be extended by additional information (e.g.
module and Order No.). This data involves offline data, which can be extracted from the
associated Step7 project.
● You can create offline data using the HMIPRO CS program.
● You transfer data to the control using the HMIPRO program.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
A recording is opened in the "Trace" graphics window.
Press the "Point Mode" softkey to continuously move the cursor along
the curve.
Press the "Peak Mode" softkey to position the cursor at the highest
value.
Press the "Valley Mode" softkey to position the cursor at the lowest
value.
If you press the "Peaks" softkey, the cursor only goes to the peak-peak
values.
If you press the "Minimum" softkey, the cursor only goes to the peak-
valley values.
Software option
For faulted modules, in order that in addition to the status information, detailed
information can also be displayed, you now require the following option:
"Operating software SW HMI PRO sl RT".
18.15 PROFIBUS/PROFINET and AS-i bus diagnostics
Service and diagnostics
399