15.5

Reading in an archive with original data

The data of the original controller state is stored in the "original.arc" file. If you want to
restore the controller to the as-delivered state, you can read in the original data archive.
Precondition
You require access level 3 (user).
Procedure
15.6
Generating the complete archive
You have the option of generating an archive of the complete data of your control on an
external storage medium that you can provide to Technical Support for diagnostic purposes.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
1.
Select the "Start-up" operating area.
2.
Press the menu forward key.
3.
Press the "Start-up archive" softkey.
The "Start-up" window opens.
4.
Activate the "Read in archive of original status" checkbox and press the
"OK" softkey.
SINUMERIK Operate automatically accesses the "original.arc" file.
A window opens prompting whether you want to perform a start-up.
5.
Press the "OK" softkey.
The read-in process is started and a progress message box is displayed
in the window.
Any errors that occur are then displayed in the "Write Error Log for
Archive" window.