21.2 Safety Integrated diagnostics
Procedure
21.2.10

SI communication receive connections

The configuration as well as the status of F_ RECVDP are displayed in the SI
communication (receive)" window.
Displayed signals
The following signals of the selected connection are displayed:
● CPU-CPU communication ID
● Logical base address
● Connection number
● Maximum parameterized communication time
● Actual communication time
● Maximum communication time
● Error reaction
Error reactions that can be set:
– [0] "Alarm 27350 + STOP D/E"
– [1] "Alarm 27350"
– [2] "Alarm 27351 (self clearing)"
– [3] "No reaction"
● Error
● Diagnostics error code
● Substitute values active
448
1.
The "SI communication (general)" window with the communication data
is opened.
2.
Press the "Send connection" softkey.
The "SI communication (send)" window is opened.
3.
Press the "Connection +" or "Connection -" softkey to select the
connection whose data you wish to display.
4.
Press the "Display SPL connection" softkey in order to display
additional details, e.g. connection data that has been set.
The softkey is only available if send connections have been configured.
5.
Press the "Display connection" softkey to return to the window with the
send connections of the selected connection.
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1