Siemens SINUMERIK 840D sl Commissioning Manual page 231

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

● Path
● File name:
Example: Switching off existing filters
To switch off the existing Siemens filter - without overwriting the filter - proceed as follows:
1. An "empty" filter switches off all previously set filters.
2. For the effect of the filters, the order in which they are set is important:
Example of the filtering of alarms 700000 to 700200:
<CONFIGURATION>
</CONFIGURATION>
Result
For the changes to the protocol settings to take effect, restart SINUMERIK Operate.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Environment variables can also be incorporated in the path, e.g. for the installation
directory: $(HMI_INSTALL_DIR).
A 3-digit number and the file extension "hmi" are automatically added to the specified file
name during operation, e.g. "slaepp_123.xml". The number is automatically increased
when:
– The file has reached the maximum size (DiskCare = 0), or
– The specified period has elapsed (DiskCare > 0).
Older files are deleted.
Note
The CompactFlash card only allows a limited number of write cycles! Therefore,
ensure that the storage is only performed when there is a justifiable need! The alarm
log is not saved in the default configuration.
Knowledge of the filter designation is not required.
siemens → addon → oem → user
<Protocol>
<Filters>
<Filter_00 type="QString" value="" />
<Filter_01 type="QString" value="CLEARINFO NOT 15 AND AlarmID LOWER
700000"/>
<Filter_02 type="QString" value="CLEARINFO NOT 15 AND AlarmID HIGHER
700200"/>
</Filters>
</Protocol>
Configuring alarms
13.3 Configuring an alarm log
225