Siemens SINUMERIK 840D sl Commissioning Manual page 805

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

1.4
Displays during system booting
Behavior of the LEDs when booting
Of the LEDs on the front panel of the NCU, only the RDY LED and its status is important
when booting up the NCU.
LED:
LED designations:
RDY
RUN STOP SU/PF
SF DP1 DP2 OPT
Orange
Orange
Slowly flashing
Set by PLC/option module
orange (0.5 Hz)
Slowly flashing
Set by PLC/option module
orange/green
(0.5 Hz)
OFF
Set by PLC/option module
green/red flashing
Set by PLC/option module
0.5 Hz)
red
Set by PLC/option module
red (5 Hz)
Set by PLC/option module
SINAMICS faults and alarms, also see: SINAMICS S120/S150 List Manual (LH1)
Load BIOS
7-segment
display
NCU operating system (IM7)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Meaning
00
Before loading the Master Boot Record (MBR) from the CompactFlash Card
01
Before starting the Master Boot Record (MBR) codes
02
Master Boot Record (MBR) code started
03
Second stage of the boot loader started, before reading the configuration file
04
Before loading the kernel
05
Before starting the kernel
1.4 Displays during system booting
State/phase
BIOS boot
Booting up the kernel
Phase 2: Initialization of the
driver
Booting the basic system
Phase 3: Initialization of the
basic system
NRK/NCK outputs
Basic system shutdown
Kernel shutdown
SINAMICS fault
System settings
7-segment display
Post codes, see table: Load
BIOS
1
See table: Load operating
system
See table: NRK/NCK outputs
OFF
OFF
---
9

Advertisement