Example
MSG
18.8.6
Advanced settings
You define the size of the log file of the action log in the "actlog.ini" configuration file.
Procedure
1. You can copy a sample configuration file "actlog.ini" from the following directory:
2. Save or create the file in the /oem/sinumerik/hmi/cfg or
3. Open the file and after "; ActionLogSize=", enter the file size (in bytes).
"actlog.ini" configuration file
Template for the configuration of Action Log
;
; To activate the settings remove the
; commentary ';' at the beginning of the line
[ActionLogSettings]
;To change the path of the internal action log file use the following setting
;ActionLogPath=/user/sinumerik/hmi/ac_log/action.com
;To change the size of the internal action log file use the following setting
;ActionLogSize=5000000
;To change the path of the internal crash log file use the following setting
;CrashLogPath=/user/sinumerik/hmi/ac_log/crash.com
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
ALARM_ON
8020
POWER ON
set
DETAILS:
Mode: JOG Program: canceled Channel: interrupted
Program-Level information:
Level Program running:
1
/_N_MPF0
/siemens/sinumerik/hmi/template/cfg.
/user/sinumerik/hmi/cfg directory.
: Option 'activation of more than 1 channels' not
Service and diagnostics
18.8 Action log
20.02.2009
14:25:37
Invoc
Offset
0
0
347