Deactivating Program Test - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

8.5

Deactivating program test

There are several program test options to test and run-in a part program that are executed
using the "Program Test" function.
This function is active as standard. You can select the program test in the "Machine"
operating area, in the "Program control" window and using the "PRT" check box.
Deactivating the program test
You can deactivate the program test using the following configuration machine data. "PRT"
is no longer displayed in the status line.
MD51039 $MNS_PROGRAM_CONTROL_MODE_MASK
Bit 0 = 0
The test option is described in the following documentation:
References
Function Manual, Basic Functions, Mode Group, Channel, Program Operation, Reset
Behavior (K1)
8.6
Activating the "Teach In" function
Activate TEACH IN
The TEACH IN function is activated in part via the general configuration machine data.
Settings
MD51034 $MNS_TEACH_MODE
Bit 0 = 1
Bit 1 = 1
Access to the function still depends on access rights.
MD51045 $MNS_ACCESS_TEACH_IN
= 7
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Function program test not available
The "Teach progr." softkey is displayed. The approached position is accepted into the
program with the "Accept" softkey, default value.
The acceptance of the teach-in block can be blocked by the PLC.
DB19.DBX13.0 = 0 Block is accepted
DB19.DBX13.0 = 1 Block is not accepted
The protection level for the execution of traversing movements to MDA buffer / part
program for TEACH IN is specified, default value.
Customizing the "Machine" operating area
8.5 Deactivating program test
Options for machine - program
control
Protection level TEACH IN
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents