Settings of the factory network

The configuration for the network interface, active protocols and firewall exceptions of the
company network are performed in the Settings of the Factory Network window.
Setting
Gateway
DNS server
Time server
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
1.
The network overview is open.
2.
Press the "System network" softkey.
The "Settings of the System Network" window opens.
3.
Press the "Change" softkey to edit settings.
Configuring the network
16.3 Settings of the factory network
Description
If this value is not empty, the host specified there
is used as the default gateway, which means that
all IP packets that cannot be directly assigned are
sent here for routing.
If DNS name servers are specified here
(maximum three), then they must be used to
resolve symbolic host names, i.e. at most of the
points where an IP address is expected, a
computer name can also be used instead.
The name server setting is also sent to your
DHCP client (TCU, PG) via the DHCP server of
the NCU, so that this can also work with symbolic
names.
Here you can specify up to three NTP servers
(UDP/123) that can be used by the NTPD on the
NCU for time synchronization.