4. Select "Permissions" and activate the "Change" square for all the users in the "Allow"
Procedure
The following steps must be carried out on the PCU:
1. Start the ServiceCenter with "Start Backup/Restore console".
2. Maintain the pre-setting of the "Network Options" on the PCU:
1. In the ServiceCenter, select the service task "Backup/Restore a Disk Image".
2. Establish a network connection to the released directory, e.g. \\SIEMENS-
3. Restore the hard disk of the PCU using the ghost image.
See also
How to backup and restore the hard disk (Page 78)
How to create a service system for PCU (Page 71)
PCU-Basesoftware (IM8)
Commissioning Manual, 02/2012, 6FC5397-1DP40-3BA0
column so that files can be saved in this directory (e.g. the ghost image).
IP address of PCU:
IP address of PG/PC:
ABC4711\PCU_Backup.
Note
If the transfer is interrupted during the "Restore" process, no consistent system is
available on the hard disk, i.e. the "Restore" process cannot be repeated because the
PCU no longer boots up.
In this event, the "Emergency Boot System" on the USB memory store is used.
4.2 Operating the service PC or the PG on the network
192.168.214.241
with subnet screen form 255.255.255.0
192.168.214.250
with subnet screen form 255.255.255.0