Siemens SINUMERIK 840D sl Commissioning Manual page 844

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Configuring the system
2.5 Description of the actions
2.5.11
Port status
Description
Syntax:
Alternative names:
Authorization level:
Mode of operation
The command "sc portstatus" can be used to query whether a certain port in the firewall has
been opened. Option "-x127" must be specified if X127 is intended as the firewall instead of
X130. The port specification looks exactly the same as it does for "sc openport", e.g.
"tcp/102". However, at this point, no names are permitted and the specified source-IP must
be unique.
The following status is output:
● "Port not open" with exit status 1.
● "Port is open (rule ID is <N>)." and exit status 0.
2.5.12
Restart
Description
Syntax:
Alternative names:
Authorization level:
With the action "sc restart" the specified subsystems are first stopped and then restarted with
the following secondary condition: Dependent subsystems are also restarted with a restart.
Syntax
'hmi', 'nck' or any other subsystem names can be used for the subsystems. Several
subsystems can also be specified one after the other, which are then started or stopped –
including all of the required dependencies. It is also possible to start and stop all subsystems
with the exception of those specified. To do this you write an exclamation mark "!" in front of
the list.
48
The ID is also supplied which you must specify for "sc closeport".
sc portstatus [-x127] PORTSPEC SOURCE
---
service
sc restart all|system|network| [!]SUBSYSTEM
reboot
service
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
NCU operating system (IM7)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents