Backing Up The Hardware Configuration - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data backup

15.3 Backing up the hardware configuration

15.3
Backing up the hardware configuration
The hardware is configured via the system data blocks (SDB) and only these are stored in
the archive.
Procedure
15.4
Creating an archive with original data
You can select this type of start-up in order to save the original status of the controller. The
files are archived in the "original.arc" file.
The file is stored on the CompactFlash card in the Archives/Manufacturer directory.
If there is no "original.arc" file in the directory, it is recommended that an archive be
generated from the data of the original controller state as delivered.
As for "Create start-up", control components can be saved individually or jointly.
282
1.
Select the "Start-up" operating area.
Press the menu forward key.
2.
Press the "Start-up archive" softkey.
The "Start-up" window opens.
3.
Activate "Create PLC hardware upgrade archive (SDBs only)" and press
the "OK" softkey.
The "Create PLC hardware upgrade archive (SDBs only): Select
Storage Location" window opens.
4.
Select the desired storage location in the displayed data tree.
- OR -
Press the "New directory" softkey to create a separate directory.
The "New Directory" window opens.
5.
Enter the required name and press the "OK" softkey.
The directory is created below the created folder.
6.
Press the "OK" softkey.
The "Generate Archive: Name" window opens.
The file type of the archive is ARC and is displayed in the window. Enter
the desired name and press the "OK" softkey.
The archive is generated and stored in the selected directory.
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1