Siemens SINUMERIK 840D sl Commissioning Manual page 372

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Service and diagnostics
18.11 Station-related network diagnostics
• DNS server 1, DNS server 2
Domain Name Server
• Gateway
• Note
All information that is not available is marked in the relevant table line with a hyphen "-".
Modifiable parameters
The following parameters of the company network adapter (X130) can be set by selecting
the "Address type":
● Address type
● IP address
● Subnet mask
● DNS server 1 and 2
● Gateway (applies for system and company network)
Address types
● DHCP
The values for the settable parameters IP address, subnet mask, DNS server 1, DNS
server 2 and gateway are defined automatically by the DHCP server, in accordance with
the entry in the "basesys.ini".
● Manual
The values for the settable parameters IP address, subnet mask, DNS server 1, DNS
server 2 and gateway can be specified manually; these are then stored in the
"basesys.ini".
References
For additional information about network configuration, please refer to the following
documentation:
SINUMERIK 840D sl, Operator Components and Networking (IM5)
366
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
SINUMERIK Operate (IM9)