Safety Integrated

21.2 Safety Integrated diagnostics

Procedure
See also
View of the axes (Page 431)
21.2
Safety Integrated diagnostics
21.2.1
Status display for NCK Safety Integrated
The status display shows signals or values with NCK and drive information for a selected
axis.
438
1.
Select the "Startup" operating area.
2.
Press the menu advance key and the "Safety" softkey.
3.
Press the "View settings" softkey.
The "Safety Integrated Settings" window opens.
The configured limits for safe operating stop (SBH) and safely limited
speed (SG) are displayed.
4.
Press the "Show safe limit pos." softkey if you wish to display the
configured directions and limits of the software limit switches (SE).
5.
Press the "Show Safe Cams" softkey if you wish to display the positions
and assignments of the safe cams (SN).
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1